LCDB2 series | 02 | 04 | 05 | 07 | 08 | 10 | 12 | 13 | 15 | 18 | 20 | 23 | 26 | 28 |
Power | Phase/Voltage | Single-phase 220VAC | Single/three phase 220VAC |
Allowed voltage regulatiion |
170~255VAC |
Allowed frequency regulation | 50/60 Hz±5% |
Cooling way | Natural cooling | Fan cooling |
Encoder/feedback | 2500ppr/10000pulse/rad |
Primary loop control mode | SVPWM control |
Manipulation mode | Manual/auto |
Retrogradation resistance | Built-in |
Position control mode | Maximum input pulse frequency | Poor transport:500kpps open transport:200kpps |
Pulse instruction mode | Pulse+symbol:A+B phase; CCW pulse +CW pulse |
Instruction control mode | External pulse control |
Instruction smooth mode | Low pulse smoothing filter |
Electronic gear ratio | Electronic gear N/M time N:1~3276/M:1:32767(1/127 |
Torque limitation | Parameter setting way |
Feed-forward compensation | Parameter setting way |
Speed control mode | Analogy Input | Voltage range | 0~10VDC |
Input resistance | 20kΩ |
Time constant | 2.2μs |
Overload allowed rehearsal | 200% rated output 8 s |
Instruction control mode | External analogy control/internal temporary control |
Instruction smooth mode | Low pass and S curve smoothing filter |
Torque limitation | Parameter setting mode |
Bandwidth | Up to 250HZ |
Speed calibration ratio | External load rated change(0~100%)max 0.01% |
Power ±10% change max 0.01% |
Environment temperature(0~50 centigrade )max 0.01% |
Torque control mode | Input | Servo start, abnormal reset ,switch gain clear pulse counting register emergency stop down or counterclockwise running limit is prohibited |
Internal register control command, speed limit orders, location speed mixed mode command options, speed mixed mode command options, position torque mixed mode command options |
Output | A/B/Z differential output(line drive)/Z phase open collector |
Servo start preparation, servo, zero speed detection, speed, position arrived, the torque limit |
Electromagnetic brake control of servo alarm output, output, complete |
Protection | Over current, over voltage, under voltage, overheating, load, velocity error is too large, the position error is too large, detector is unusual, abnormal retrogradation, communication is unusual, abnormal memory |
Communication interface | RS-232/RS485 RS422 ACSII RTU |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|