Features:
1. Voltage input range: 18V ~ 50VDC
2. Maximum peak current: 7A
3. Subdivision range: 200 ~ 51200ppr
4. Signal input: differential / single-ended, pulse / direction
5. Impulse response limit frequency: 200KHZ
6. Power-on parameter auto-tuning function
7. Closed-loop vector control to ensure that the motor high-speed high-torque output, while ensuring that the motor does not lose step
8. With over-voltage, over-current, tracking error tolerance and other protection
Main parameters:
1. Electrical Specifications
Parameter | LCDA357H |
Minimum value | Typical value | Maximum value | unit |
Max peak current | - | - | 7 | A |
Input power voltage | 20 | 36 | 50 | Vdc |
Logic input current | 7 | 10 | 16 | mA |
Pulse frequency | - | - | 200 | kHz |
2.Interface definition
1) Motor & power input port
Symbol | Name | Explanation |
U- | Motor U phase winding |
|
V | Motor V phase winding |
|
W | Motor W phase winding |
|
Vdc | Input DC power supply positive | +20V~+50V |
GND | Input power ground | 0V |
|
|
|
2) Encoder signal input port:
Symbol | Name |
EB+ | Motor encoder B phase positive input |
EB- | Motor encoder B phase negative input |
EA+ | Motor encoder A positive input |
EA- | Motor encoder A phase negative input |
VCC | Encoder power supply |
EGND | Encoder power ground |
Name | Explanation |
PUL+ | Pulse input signal: pulse effective edge adjustable, the default pulse rising edge is valid; in order to reliably respond to the pulse signal, the pulse width should be greater than 1.2μs. Such as the use of +12 V or +24 V when the need to string 3K resistance |
PUL- |
DIR+ | Direction input signal: high / low level signal, in order to ensure reliable reversing of the motor, the direction of the signal should be preceded by pulse signal at least 5μs to establish, such as the use of +12 V or +24 V string 3K resistor. |
DIR- |
ENA+ | Enable control signal: This input signal is used to enable or disable. When ENA +, ENA- have input, the drive will cut off the motor phase to make the motor in a free state. When this function is not required, the terminal can be left floating. Such as the use of +12 V or +24 V when the need to string 3K resistance |
ENA- |
Pend+ | Positioning completion signal positive side |
Pend- | Positioning completion signal negative |
ALM+ | Alarm output positive terminal |
ALM- | Alarm output negative terminal |