MC856 Nema34 digital driver

Product Name: MC856 Nema34 digital driver
上市日期:2017-03-20
产品型号:

 MC856 digital low-voltage stepper motor driver, using the latest 32-bit DSP technology, suitable for driving 57,86 series motor, with excellent low-speed performance. You can set any of the subdivision within 256 and the rated current within any current value, to meet the needs of most small devices applications. The use of built-in sub-sub-technology, even in the low sub-sub-conditions, but also to achieve the effect of high-segmentation, low-speed operation is very smooth, very little noise

.

 

订购热线: 86-755-6113 1663
SKYPE客服
旺旺客服
新浪微博
分享到豆瓣
  • Technical Information
  • Dimensions
  • Product Image
  • Wiring Method
  • Package Product
  • Application Areas
  • Download


 

Driver Function

operation Insulation

Microsteps Sudivision setting

SW5-SW8 four DIP switches to set the drive micro-step subdivision, a total of 15 steps of mic ro-step breakdown. When the user sets the subdivision, the drive should be stopped first. For details on the numberof microsteps,Please according to the drive panel.

 Working current setting

SW1-SW3 three DIP switches to set the drive output current, the output current of a total of 8 floor.Details on setting the output current,refer to the description of the driver panel.

Automatic half current Function

SW4 can be used to set the automatic semi-flow function of the drive. OFF mean the quiescent current is set to half of the dynamic current, and ON means the quiescent current is the same as the dynamic current SW4 should be set to OFF for general use, resulting in reduced heat generation in the motor an the drive, resulting in improved reliability. Approximately 0.4 seconds after the pulse train is stopped, the current automatically reduced by 50% (60% of the actual value) and the calorific value is oretically reduced by 36%.

    Signal interface

PUL + and PUL- are the positive and negative terminals of the control pulsesignal;DIR + and DIR- are the positive and negative terminalsof the directional signal;ENA + and ENA- are the positive & negative terminals of the enable signal.

 Motor interface

A + and A- are connected to the positive and negative terminals of the A-phase winding of the stepping motor; B + and B- are connected to the positive and negative terminals of the B-phase winding of the stepping motor.When A, B two-phase winding exchange,direction of the motor can be reversed

      Indicator light

The driver has two red and green lights. The green light is the power indicator, the green light is on when the driver is powered on. The red light is the fault indicator. When the overvoltage or overcurrent fault occurs, the fault light is on.Fault clear, the red light off. When the drive fails, the fault can only be cleared by re-powering up and re-enabling it.

    Power supply Port

DC power supply, the input voltage range: 20V-80VDC,Power more than 200W

  Installation Notes

Driver dimension :117x78x34mm ,installation the hole spacing of 143mm can be

horizontal can be horizontal or vertical mounting (suggest the vertical installation) when installed ,mke it close to the metal cabinet to facllitate heat .

 

MC856 driver with eight DIP switch set subdivision accuracy, dynamic current and half-flow / full-flow, described in detail as follows:

 

MC856 Nema34 digital driver

 

 

Working current setting :

 

Peak currentMean current

SW1

SW2

SW3

1.4A

1.0A

off

off

off

2.1A

1.5A

on

off

off

2.7A

1.9A

off

on

off

3.2A

2.3A

on

on

off

3.8A

2.7A

off

off

on

4.3A

3.1A

on

off

on

4.9A

3.5A

off

on

on

5.6A

4.0A

on

on

on

 

 

Microstep settings :

 

Step/turn

SW5

SW6

SW7

SW8

400

off

on

on

on

800

on

0ff

on

on

1600

off

off

on

on

3200

on

on

off

on

6400

off

on

off

on

12800

on

off

off

on

25600

0ff

off

off

on

1000

on

on

on

off

2000

off

on

on

off

4000

on

off

on

off

5000

off

off

on

off

8000

on

on

off

off

10000

off

on

off

off

20000

on

off

off

off

25000

off

off

off

off

 

 

 

MC856 Nema34 digital driver


MC856 Nema34 digital driver

MC856 Nema34 digital driver

MC856 Nema34 digital driver

 

 MC856 Nema34 digital driver

产品相关产品 / Products 更多>>
2017 - 05 - 19
Electrical Specifications Motor modelStep/angle LengthHolding torqueCurrent Resistance InductanceRotor inertiaLead wireWeight°mmN.MAΩMHg.cm2NO.KgLC86HS68011.8663.33.00.61.6100...

 

 Suitable for all kinds of motion control equipment and instruments, such as: electronic processing and testing,semiconductor packaging, laser cutting and welding, laser phototypesetting, packaging machinery, engraving machines, marking machines, cutting machines, clothing plotter, CNC machine tools, automation Assembly equipment. Low noise, high-speed performance and cost-effective competition, the field of choice.

/Private/ProductFiles/084285d33c6dab3c8e1f.pdf
Current product download——> Click to Download
Recommended Products / 热卖产品 More
2017 - 03 - 20
Features: 1. Voltage input range: 18V ~ 50VDC2. Maximum peak current: 7A3. Subdivision range: 200 ~ 51200ppr4. Signal input: differential / single-ended, pulse / direction5. Impulse response limit frequency: 200KHZ6. Power-on parameter auto-tuning function7. Closed-loop vector control to ensure that the motor high-speed high-torque output, while ensuring that the motor does not lose step8. Wi...
2017 - 03 - 19
Driver Functionoperation InsulationMicrosteps Sudivision settingSW5-SW8 four DIP switches to set the drive micro-step subdivision, a total of 15 steps of mic ro-step breakdown. When the user sets the subdivision, the drive should be stopped first. For details on the numberof microsteps,Please according to the drive panel. Working current settingSW1-SW3 three DIP switc...
2017 - 03 - 20
Features: 1. Voltage input range: 150 ~ 230VAC2. Quiescent current and dynamic current can be set at 0 ~ 6A3. Closed-loop vector control to ensure that the motor high-speed high-torque output, while ensuring the motor does not lose step4. Built-in sub-sub-low-speed low-level operation can also be very smooth5. Parameter automatic setting function6. Current dynamic control greatly reduces the ...
2019 - 03 - 22
A4 Servo driver standard specificationstandard specificationInput powerMain loop power single/3 phase : 200-240VAC   50/60HzControl loop powersingle phase :220-240VAC 50/60HzWorking condition TemperatureWorking temperature: 0-55 ° C Storage temperature -20 ° C -60 ° C HumidityWork / save ≤ 90% RH or less (no condensation)Altitude ≤1000mVibration≤5.88M/S...
友情链接
  • 友情链接
  • Mobile Website
    Mobile Website
    WeChat Public No.
    WeChat Public No.
Pre/after-sale service:
86 135 1084 4098
86 159 0755 7836
Copyright ©2017  Shenzhen Xinli Chuan Electric Co., Ltd.   ICP 13007763号-1


犀牛云提供企业云服务
X
1

QQ设置

4

阿里旺旺设置

99

电话号码管理

6

二维码管理

展开