Welcome to Shenzhen Xinli Chuan Electric Co., Ltd.

Shenzhen Xinli Chuan Electric Co., Ltd.
Product Categories
Products Product
型号:
时间: 2017 - 03 - 20
Features: 1. Voltage input range: 18V ~ 50VDC2. Maximum peak current: 7A3. Subdivision range: 200 ~ 51200ppr4. Signal input: differential / single-ended, pulse / direction5. Impulse response limit frequency: 200KHZ6. Power-on parameter auto-tuning function7. Closed-loop vector control to ensure that the motor high-speed high-torque output, while ensuring that the motor does not lose step8. With over-voltage, over-current, tracking error tolerance and other protection   Main p...
Click to Enter
型号:
时间: 2017 - 03 - 19
Driver Functionoperation InsulationMicrosteps Sudivision settingSW5-SW8 four DIP switches to set the drive micro-step subdivision, a total of 15 steps of mic ro-step breakdown. When the user sets the subdivision, the drive should be stopped first. For details on the numberof microsteps,Please according to the drive panel. Working current settingSW1-SW3 three DIP switches to set the drive output current, the output current of a totalof 8 floor.Details on setting the ...
Click to Enter
型号:
时间: 2017 - 03 - 20
Features: 1. Voltage input range: VAC: 20 ~ 70V OR VDC: 30 ~ 100V2. Maximum peak current: 6A3. Subdivision range: the default 4000 / rev, through the debug board can be set to any subdivision (200-51200)4. Pulse limit frequency: 200KHZ5. Signal input: pulse, direction and enable signal6. Output signal: in place signal and fault output signal7. Motor encoder feedback: AB differential input8. Closed-loop vector control to ensure that the motor high-speed large torque output, while ensuring th...
Click to Enter
型号:
时间: 2017 - 03 - 19
Driver Functionoperation InsulationMicrosteps Sudivision settingSW5-SW8 four DIP switches to set the drive micro-step subdivision, a total of 15 steps of mic ro-step breakdown. When the user sets the subdivision, the drive should be stopped first. For details on the numberof microsteps,Please according to the drive panel. Working current settingSW1-SW3 three DIP switches to set the drive output current, the output current of a totalof 8 floor.Details on setting the ...
Click to Enter
型号:
时间: 2017 - 03 - 20
Features: 1. Voltage input range: 50V ~ 80VAC2. Maximum peak current: 8A3. Subdivision range: 200 ~ 51200ppr4. Signal input: differential / single-ended, pulse / direction5. Impulse response maximum frequency: 200KHZ6. External digital debugging panel for easy parameter setting and monitoring7. Serial communication function, current, subdivision can be adjusted, signal edge, alarm output logic and other functions adjustable8. Closed-loop vector control to ensure that the motor high-speed hi...
Click to Enter
型号:
时间: 2017 - 03 - 20
Driver Functionoperation InsulationMicrosteps Sudivision settingSW5-SW8 four DIP switches to set the drive micro-step subdivision, a total of 15 steps of mic ro-step breakdown. When the user sets the subdivision, the drive should be stopped first. For details on the numberof microsteps,Please according to the drive panel. Working current settingSW1-SW3 three DIP switches to set the drive output current, the output current of a total of 8 floor.Details on setting the...
Click to Enter
型号:
时间: 2017 - 03 - 20
Features: 1. Voltage input range: 150 ~ 230VAC2. Quiescent current and dynamic current can be set at 0 ~ 6A3. Closed-loop vector control to ensure that the motor high-speed high-torque output, while ensuring the motor does not lose step4. Built-in sub-sub-low-speed low-level operation can also be very smooth5. Parameter automatic setting function6. Current dynamic control greatly reduces the motor heat, ultra-low vibration noise7. External digital debugging panel for easy parameter setting ...
Click to Enter
型号:
时间: 2017 - 03 - 20
Driver Functionoperation InsulationMicrosteps Sudivision settingSW5-SW8 four DIP switches to set the drive micro-step subdivision, a total of 15 steps of mic ro-step breakdown. When the user sets the subdivision, the drive should be stopped first. For details on the numberof microsteps,Please according to the drive panel. Working current settingSW1-SW3 three DIP switches to set the drive output current, the output current of a total of 8 floor.Details on setting the...
Click to Enter
型号:
时间: 2017 - 05 - 19
Features: 1. Voltage input range:  VDC: 30 ~ 100V2. Maximum peak current: 6A3. Subdivision range: the default 4000 / rev, through the debug board can be set to any subdivision (200-51200)4. Pulse limit frequency: 200KHZ5. Signal input: pulse, direction and enable signal6. Output signal: in place signal and fault output signal7. Motor encoder feedback: AB differential input8. Closed-loop vector control to ensure that the motor high-speed large torque output, while ensuring that the moto...
Click to Enter
型号:
时间: 2017 - 05 - 19
Features: 1. Voltage input range: DC: 20V ~ 50V (recommended 36V or more)2. Maximum peak current: 6A3. Subdivision range: 400 ~ 51200ppr4. Pulse form: pulse + direction, CW / CCW5. Impulse response frequency: 0 ~ 200kHz6. Logic input current: 10 ~ 20mA7. Power-on parameter auto-tuning function8. Closed-loop vector control to ensure that the motor high-speed high-torque output, while ensuring that the motor does not lose step9. With over-voltage, over-current, tracking error tolerance and ot...
Click to Enter
型号:
时间: 2020 - 10 - 27
Features:1. Voltage input range: DC: 20V ~ 50V (recommended 36V or more)2. Maximum peak current: 6A3. Subdivision range: 400 ~ 51200ppr4. Pulse form: pulse + direction, CW / CCW5. Impulse response frequency: 0 ~ 200kHz6. Logic input current: 10 ~ 20mA7. Power-on parameter auto-tuning function8. Closed-loop vector control to ensure that the motor high-speed high-torque output, while ensuring that the motor does not lose step9. With over-voltage, over-current, tracking error tolerance and other pr...
Click to Enter
50页次1/5首页<<12345>>尾页
友情链接
  • 友情链接
  • Mobile Website
    Mobile Website
    WeChat Public No.
    WeChat Public No.
Pre/after-sale service:
86 135 1084 4098
86 159 0755 7836
Copyright ©2017  Shenzhen Xinli Chuan Electric Co., Ltd.   ICP 13007763号-1


犀牛云提供企业云服务
X
1

QQ设置

4

阿里旺旺设置

99

电话号码管理

6

二维码管理

展开